Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 63
Filtrar
1.
Pediatr Transplant ; 28(3): e14706, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38553789

RESUMO

BACKGROUND: Heterotaxy syndrome (HS) is a defect in lateralization which often results in complex intra and extracardiac abnormalities. Orthotropic heart transplantation (OHT) in HS involves intricate and individualized modifications to surgical technique. Post-OHT outcomes are worse in patients with HS, however, the impact of post-OHT residual lesions has not yet been characterized. METHODS: Patients with HS who underwent OHT at Ann & Robert H. Lurie Children's Hospital of Chicago between January 2012 and June 2023 were identified. Patients were excluded if follow-up data was not available due to follow up at a different institution of early mortality. Pre-OHT clinical data, surgical data, and post-OHT surgical and catheterization data were collected. RESULTS: Two early mortalities were excluded from analysis, leaving 15 patients in the study cohort. Median age at OHT was 3.7 years (range: 0.7-15.4). Nine out of 15 patients were diagnosed with residual lesions requiring intervention at a median of 188 days post transplantation. All interventions on residual lesions occurred via catheterization. Overall mortality rate was 27% (4/15) with all deaths occurring in patients with residual lesions (4/9 patients, 44%). 83% (10/12) of lesions were diagnosed via catheterization, and 83% (10/12) of lesions of occurred in the first year after transplant. CONCLUSIONS: Patients with HS are at high risk for residual lesions after OHT, which may contribute to increased mortality. Comprehensive invasive diagnostics were required to diagnose residual lesions, which were all addressed percutaneously.


Assuntos
Transplante de Coração , Síndrome de Heterotaxia , Criança , Humanos , Lactente , Pré-Escolar , Adolescente , Síndrome de Heterotaxia/complicações , Síndrome de Heterotaxia/cirurgia , Estudos Retrospectivos
2.
Pediatr Transplant ; 28(3): e14705, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38528753

RESUMO

BACKGROUND: The relationship between histopathologic and molecular ("MMDx"®) assessments of endomyocardial biopsy (EMB) and serum donor-derived cell-free DNA (ddcfDNA) in acute rejection (AR) assessment following pediatric heart transplantation (HT) is unknown. METHODS: EMB sent for MMDx and histopathology from November 2021 to September 2022 were reviewed. MMDx and histopathology results were compared. DdcfDNA obtained ≤1 week prior to EMB were compared with histopathology and MMDx results. The discrimination of ddcfDNA for AR was assessed using receiver-operating curves. FINDINGS: In this study, 177 EMBs were obtained for histopathology and MMDx, 101 had time-matched ddcfDNA values. MMDx and Histopathology displayed moderate agreement for T-cell-mediated rejection (TCMR, Kappa = 0.52, p < .001) and antibody-mediated rejection (ABMR, Kappa = 0.41, p < .001). Discordant results occurred in 24% of cases, most often with ABMR. Compared with no AR, ddcfDNA values were elevated in cases of AR diagnosed by both histopathology and MMDx (p < .01 for all). Additionally, ddcfDNA values were elevated in injury patterns on MMDx, even when AR was not present (p = .01). DdcfDNA displayed excellent discrimination (AUC 0.83) for AR by MMDx and/or histopathology. Using a threshold of ≥0.135%, ddcfDNA had a sensitivity of 90%, specificity of 63%, PPV of 52%, and NPV of 94%. CONCLUSIONS: Histopathology and MMDx displayed moderate agreement in diagnosing AR following pediatric HT, with most discrepancies noted in the presence of ABMR. DdcfDNA is elevated with AR, with excellent discrimination and high NPV particularly when utilizing MMDx. A combination of all three tests may be necessary in some cases.


Assuntos
Ácidos Nucleicos Livres , Doxorrubicina/análogos & derivados , Transplante de Coração , Humanos , Criança , Rejeição de Enxerto/diagnóstico , Rejeição de Enxerto/genética , Biópsia , RNA Mensageiro
3.
J Thorac Cardiovasc Surg ; 167(2): 413-419, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37406764

RESUMO

OBJECTIVE: Cross-sectional imaging allows identification of rare patients with a vascular ring and circumflex aorta. The key diagnostic feature is crossing of the transverse aortic arch from right to left posterior to the trachea and superior to the carina in a patient with a right aortic arch. We evaluated our patients who received an aortic uncrossing procedure. METHODS: We reviewed all patients who underwent aortic uncrossing from 2002 to 2022. All patients received preoperative computed tomography imaging and bronchoscopy. RESULTS: Eleven patients ranging in age from 1.5 to 10 years (median 4 years) underwent aortic uncrossing. Two patients had prior left ligamentum division, and 3 patients had prior left aortic arch division. All had significant clinical symptoms. Eight patients had deep hypothermic circulatory arrest (mean 34 minutes), and 3 patients had antegrade cerebral perfusion (median, 28 minutes). Patch material was not used for aortic augmentation, and no patient underwent a posterior tracheopexy or rotational esophagoplasty. Postoperative length of stay ranged from 4 to 31 days (median, 5 days). One patient required a temporary tracheostomy for bilateral recurrent laryngeal nerve paresis, which recovered. One patient required an aortic extension graft to alleviate esophageal compression from an unusual ectatic esophageal course. All patients had relief of airway symptoms and dysphagia. CONCLUSIONS: In properly selected patients with a right aortic arch and circumflex aorta, aortic uncrossing is a safe and effective therapy to treat airway and esophageal compression. The procedure can be conducted with deep hypothermic circulatory arrest or antegrade cerebral perfusion. Careful attention to the location of the esophagus and recurrent laryngeal nerves is required.


Assuntos
Aorta Torácica , Aorta , Humanos , Lactente , Pré-Escolar , Criança , Aorta/diagnóstico por imagem , Aorta/cirurgia , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Broncoscopia , Procedimentos Cirúrgicos Vasculares , Perfusão/métodos
4.
Pediatr Cardiol ; 45(2): 446-451, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37955720

RESUMO

Absent pulmonary valve with tricuspid atresia or tricuspid stenosis (APV-TA/TS) is an extremely rare congenital heart defect associated with significant morbidity and mortality. Compared to Tetralogy of Fallot with Absent Pulmonary Valve Syndrome, branch pulmonary arteries are not typically significantly dilated. We present the case of a newborn male prenatally diagnosed APV-TA with intact ventricular septum (IVS) and nearly discontinuous branch pulmonary arteries, the surgical strategy employed, and the salient hemodynamic factors considered in the medical decision-making.


Assuntos
Cardiopatias Congênitas , Atresia Pulmonar , Valva Pulmonar , Atresia Tricúspide , Septo Interventricular , Recém-Nascido , Masculino , Humanos , Atresia Tricúspide/diagnóstico por imagem , Atresia Tricúspide/cirurgia , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/anormalidades , Artéria Pulmonar/diagnóstico por imagem , Cardiopatias Congênitas/cirurgia , Atresia Pulmonar/diagnóstico por imagem , Atresia Pulmonar/cirurgia
5.
Magn Reson Med ; 90(6): 2510-2523, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37526134

RESUMO

PURPOSE: After epicardial cardiac implantable electronic devices are implanted in pediatric patients, they become ineligible to receive MRI exams due to an elevated risk of RF heating. We investigated whether simple modifications in the trajectories of epicardial leads could substantially and reliably reduce RF heating during MRI at 1.5 T, with benefits extending to abandoned leads. METHODS: Electromagnetic simulations were performed to assess RF heating of two common 35-cm epicardial lead trajectories exhibiting different degrees of coupling with MRI incident electric fields. Experiments in anthropomorphic phantoms implanted with commercial cardiac implantable electronic devices confirmed the findings. Both electromagnetic simulations and experimental measurements were performed using head-first and feet-first positioning and various landmarks. Transfer function approach was used to assess the performance of suggested modifications in realistic body models. RESULTS: Simulations (head-first, chest landmark) of a 35-cm epicardial lead with a trajectory where the excess length of the lead was looped and placed on the inferior surface of the heart showed an 87-fold reduction in the 0.1 g-averaged specific absorption rate compared with the lead where the excess length was looped on the anterior surface. Repeated experiments with a commercial epicardial device confirmed this. For fully implanted systems following low-specific absorption rate trajectories, there was a 16-fold reduction in the average temperature rise and a 28-fold reduction for abandoned leads. The transfer function method predicted a 7-fold reduction in the RF heating in 336 realistic scenarios. CONCLUSION: Surgical modification of epicardial lead trajectory can substantially reduce RF heating at 1.5 T, with benefits extending to abandoned leads.


Assuntos
Calefação , Próteses e Implantes , Humanos , Criança , Coração , Temperatura , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Ondas de Rádio , Temperatura Alta
6.
Circ Cardiovasc Qual Outcomes ; 16(9): e009638, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37539540

RESUMO

BACKGROUND: The relationship between the prenatal diagnosis of congenital heart defects (CHDs) and age at CHD surgery is poorly understood, despite the known relationships between age at surgery and long-term outcomes. The objective of this study was to determine the associations between prenatal diagnosis of CHD and age at surgery, and whether these associations differ for critical and noncritical CHDs. METHODS: This is a cohort analysis of patients aged 0 to 9 years who received their initial cardiac surgery at Ann & Robert H. Lurie Children's Hospital of Chicago between 2015 and 2021 with prenatal diagnosis as the exposure variable. All data were obtained from the locally maintained Society of Thoracic Surgeons Congenital Heart Surgery Database at Lurie Children's Hospital. We used multivariable fixed effects regression models to estimate the strength of the association of prenatal diagnosis with age at surgery among patients with critical (surgery ≤60 days) and noncritical (surgery >60 days) CHDs. RESULTS: Of 1131 individuals who met inclusion criteria, 532 (47%) had a prenatal diagnosis, 428 (38%) had critical CHDs, 533 (47%) were female, and the median age at surgery was 119 days (interquartile range, 11-309 days). After controlling for demographics, comorbidities, and surgical complexity, the mean age at surgery was significantly younger in those with prenatally versus postnatally diagnosed critical CHD (7.1 days sooner, P<0.001) and noncritical CHDs (atrial septal defects [12.4 months sooner, P=0.037], ventricular septal defects [6.0 months sooner, P<0.003], and noncritical coarctation of the aorta [1.8 months sooner, P=0.010]). CONCLUSIONS: Younger age at CHD surgery, which is associated with postsurgical neurodevelopmental and physical outcomes, is significantly associated with prenatal CHD diagnosis. This relationship was identified for both critical and noncritical CHDs.


Assuntos
Coartação Aórtica , Cardiopatias Congênitas , Gravidez , Criança , Humanos , Feminino , Lactente , Masculino , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/cirurgia , Diagnóstico Pré-Natal , Chicago
7.
J Heart Lung Transplant ; 42(11): 1546-1556, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37419295

RESUMO

BACKGROUND: We report current outcomes in patients supported with the HeartMate 3 (HM3) ventricular assist device in a multicenter learning network. METHODS: The Advanced Cardiac Therapies Improving Outcomes Network database was queried for HM3 implants between 12/2017 and 5/2022. Clinical characteristics, postimplant course, and adverse events were collected. Patients were stratified according to body surface area (BSA) (<1.4 m2, 1.4-1.8 m2, and >1.8 m2) at device implantation. RESULTS: During the study period, 170 patients were implanted with the HM3 at participating network centers, with median age 15.3years; 27.1% were female. Median BSA was 1.68 m2; the smallest patient was 0.73 m2 (17.7 kg). Most (71.8%) had a diagnosis of dilated cardiomyopathy. With a median support time of 102.5days, 61.2% underwent transplantation, 22.9% remained supported on device, 7.6% died, and 2.4% underwent device explantation for recovery; the remainder had transferred to another institution or transitioned to a different device type. The most common adverse events included major bleeding (20.8%) and driveline infection (12.9%); ischemic and hemorrhagic stroke were encountered in 6.5% and 1.2% of patients, respectively. Patients with BSA <1.4 m2 had a higher incidence of infection, renal dysfunction, and ischemic stroke. CONCLUSIONS: In this updated cohort of predominantly pediatric patients supported with the HM3 ventricular assist device, outcomes are excellent with <8% mortality on device. Device-related adverse events including stroke, infection, and renal dysfunction were more commonly seen in smaller patients, highlighting opportunities for improvements in care.

8.
World J Pediatr Congenit Heart Surg ; 14(3): 364-367, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36895120

RESUMO

Interventricular septal hematoma is a rare and life-threatening complication of pediatric cardiac surgery. Commonly seen following ventricular septal defect repair, it has also been associated with ventricular assist device (VAD) placement. Although conservative management is usually successful, operative drainage of interventricular septal hematoma occurring in pediatric patients undergoing VAD implantation should be considered.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Insuficiência Cardíaca , Comunicação Interventricular , Coração Auxiliar , Septo Interventricular , Humanos , Lactente , Criança , Coração Auxiliar/efeitos adversos , Septo Interventricular/diagnóstico por imagem , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Comunicação Interventricular/diagnóstico por imagem , Comunicação Interventricular/cirurgia , Comunicação Interventricular/complicações , Hematoma/diagnóstico por imagem , Hematoma/etiologia , Hematoma/cirurgia , Insuficiência Cardíaca/etiologia
9.
Pediatr Transplant ; 27(5): e14458, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36591815

RESUMO

BACKGROUND: Despite ubiquitous exposure to sensitizing events, most Fontan PLE patients have low panel reactive antibodies (PRA). To assess whether they are at risk for donor-specific antibody (DSA) memory response following heart transplantation (HT) when their PLE resolves, DSA profiles, incidence of rejection, and graft outcomes in Fontan recipients with and without PLE were compared. METHODS: Patient characteristics, appearance of newly detected DSA (nDSA), and graft outcomes were compared between patients with and without PLE using Wilcoxon rank-sum and Chi-squared tests. DSA burden was quantified using titers and time to nDSA, incidence of rejection, and graft outcomes were compared using Kaplan-Meier curves and the log-rank test. RESULTS: Characteristics of patients with and without PLE were similar. Lymphocyte and albumin levels were lower in the PLE group, and flow PRA were comparable. Graft failure, CAV, and ACR were similar between the two groups, but AMR occurred more frequently in the PLE group (p = .03). Nearly 50% of PLE patients experienced class II nDSA by 1-year post-HT, compared to 30% of non-PLE patients, but this difference was statistically not significant. Antibody burden did not differ between groups. CONCLUSIONS: In this cohort, PLE was associated with AMR within the first-year post-HT, despite no significant difference in nDSA. Small patient numbers limited statistical comparison of nDSA in this cohort. PLE may be a risk factor for AMR post-HT, and the possibility of a clinically important DSA memory response remains. Larger studies are necessary to better understand these preliminary findings.


Assuntos
Transplante de Coração , Enteropatias Perdedoras de Proteínas , Humanos , Enteropatias Perdedoras de Proteínas/etiologia , Rejeição de Enxerto , Anticorpos , Doadores de Tecidos , Transplante de Coração/efeitos adversos , Antígenos HLA , Estudos Retrospectivos
11.
J Thorac Cardiovasc Surg ; 166(1): 210-211, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36494208
12.
Ann Thorac Surg ; 115(5): e121-e123, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-35472409

RESUMO

We describe a 9-year-old, 25-kg child with failing single-ventricle palliation with a superior cavopulmonary anastomosis successfully supported with a HeartMate 3 ventricular assist device (Abbott) as a bridge to transplantation.


Assuntos
Derivação Cardíaca Direita , Coração Auxiliar , Criança , Humanos
13.
Annu Int Conf IEEE Eng Med Biol Soc ; 2022: 5000-5003, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-36086119

RESUMO

Infants and children with congenital heart defects often receive a cardiac implantable electronic device (CIED). Because transvenous access to the heart is difficult in patients with small veins, the majority of young children receive epicardial CIEDs. Unfortunately, however, once an epicardial CIED is placed, patients are no longer eligible to receive magnetic resonance imaging (MRI) exams due to the unknown risk of MRI-induced radiofrequency (RF) heating of the device. Although many studies have assessed the role of device configuration in RF heating of endocardial CIEDs in adults, such case for epicardial devices in pediatric patients is relatively unexplored. In this study, we evaluated the variation in RF heating of an epicardial lead due to changes in the lateral position and orientation of the implantable pulse generator (IPG). We found that changing the orientation and position of the IPG resulted in a five-fold variation in the RF heating at the lead's tip. Maximum heating was observed when the IPG was moved to a left lateral abdominal position of patient, and minimum heating was observed when the IPG was positioned directly under the heart. Clinical Relevance- This study examines the role of device configuration on MRI-induced RF heating of an epicardial CIED in a pediatric phantom. Results could help pediatric cardiac surgeons to modify device implantation to reduce future risks of MRI in patients.


Assuntos
Calefação , Ondas de Rádio , Adulto , Criança , Pré-Escolar , Humanos , Imageamento por Ressonância Magnética/efeitos adversos , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Próteses e Implantes
14.
ASAIO J ; 68(11): e207-e210, 2022 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-35439193

RESUMO

Histiocytoid cardiomyopathy (HICMP) is a rare mitochondrial cardiomyopathy associated with recurrent life-threatening arrhythmias and variable degrees of systolic dysfunction. Successful heart transplantation for HICMP has been described, but there has been no published experience with biventricular assist device (BiVAD) support for intractable arrhythmias in HICMP. We report a 13 month old girl with left ventricular noncompaction and preserved systolic function who presented in cardiogenic shock secondary to incessant ventricular arrhythmias. After failed attempts at chemical and electrical cardioversion, she underwent BiVAD implantation as bridge to transplantation. Her BiVAD course was complicated by mechanical inflow obstruction during sinus rhythm, necessitating left-sided cannulation revision from an apical to atrial inflow cannula. This maneuver resolved the obstruction and the patient was transitioned to Berlin EXCOR (Berlin Heart Inc, The Woodlands, TX) BiVADs. On Berlin pumps, she had intermittent pauses (no fill/no eject) while in sinus rhythm, felt to be due to competition from intrinsic ejection. Despite these pauses, the patient experienced an uneventful remainder of her BiVAD course (205 days total) with minimal fibrin deposition and no device-related complications. BiVAD can support pediatric patients with hemodynamically significant arrhythmias to transplantation. Atrial cannulation strategy may be preferred in cases of preserved systolic function, ventricular noncompaction, and frequent rhythm changes.


Assuntos
Cardiomiopatias , Transplante de Coração , Coração Auxiliar , Feminino , Humanos , Lactente , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/cirurgia , Átrios do Coração , Resultado do Tratamento
15.
ASAIO J ; 68(11): 1384-1392, 2022 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-35184092

RESUMO

Pediatric cardiac extracorporeal membrane oxygenation (ECMO) patients have high mortality rates. The purpose of our study was to develop and validate the Pediatric Survival After Veno-arterial ECMO (Pedi-SAVE) score for predicting survival at hospital discharge after pediatric cardiac veno-arterial (VA) ECMO. We used data for pediatric cardiac VA-ECMO patients from the Extracorporeal Life Support Organization registry (1/1/2001-12/31/2015). Development and validation cohorts were created using 2:1 random sampling. Predictors of survival to develop pre- and postcannulation models were selected using multivariable logistic regression and random forest models. ß-coefficients were standardized to create the Pedi-SAVE score. Of 10,091 pediatric cardiac VA-ECMO patients, 4,996 (50%) survived to hospital discharge. Pre- and postcannulation Pedi-SAVE scores predicted that the lowest risk patients have a 65% and 74% chance of survival at hospital discharge, respectively, compared to 33% and 22% in the highest risk patients. In the validation cohort, pre- and postcannulation Pedi-SAVE scores had c-statistics of 0.64 and 0.71, respectively. Precannulation factors associated with survival included: nonsingle ventricle congenital heart disease, older age, white race, lower STAT mortality category, higher pH, not requiring acid-buffer administration, <2 cardiac procedures, and indication for VA-ECMO other than failure to wean from cardiopulmonary bypass. Postcannulation, additional factors associated with survival included: lower ECMO pump flows at 24 hours and lack of complications. The Pedi-SAVE score is a novel validated tool to predict survival at hospital discharge for pediatric cardiac VA-ECMO patients, and is an important advancement in risk adjustment and benchmarking for this population.


Assuntos
Oxigenação por Membrana Extracorpórea , Humanos , Criança , Oxigenação por Membrana Extracorpórea/métodos , Choque Cardiogênico , Mortalidade Hospitalar , Estudos Retrospectivos , Estudos de Coortes
16.
Ann Thorac Surg ; 113(2): 630-636, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-33524348

RESUMO

BACKGROUND: Fetal diagnoses of vascular rings have been increasing. We compared management strategies and outcomes of infants with fetal diagnosis with those with postnatal diagnosis to inform recommendations regarding optimal management. METHODS: A retrospective review was performed of vascular ring operations from January 2000 to June 2019. Standard demographic data (preoperative clinical status, timing of diagnosis, cross-sectional imaging, operative and perioperative details, and clinical outcomes) were collected. Statistical analysis was performed to compare characteristics and outcomes of fetal versus postnatal diagnosis. RESULTS: Of 190 patients, 15% (n = 29) were diagnosed prenatally. Anatomic variants were double aortic arch (n = 66, 14 fetal diagnoses), right aortic arch, aberrant left subclavian artery (n = 94, 12 fetal diagnoses), circumflex aorta (n = 7, 1 fetal diagnosis), and pulmonary artery sling (n = 19, 2 fetal diagnoses). An increasing frequency of fetal diagnoses has been noted in the past 10 years. In 2012 1 of 9 patients (11%) had a fetal diagnosis, whereas in 2018 8 of 11 (72%) had a fetal diagnosis (P < .001). Patients with a fetal diagnosis were significantly younger at the time of surgery (13.1 months [interquartile range (IQR), 20.6] vs 24.0 months [IQR, 87.0], P = .029). There was no difference in postoperative complications or length of stay (3 days [IQR, 1] for fetal diagnoses vs 4 days [IQR, 3] for postnatal diagnoses, P = .50). CONCLUSIONS: Fetal diagnosis leads to the potential for expectant management of vascular ring patients. This has resulted in earlier time of intervention with no increase in postoperative morbidity. This may lead to improved long-term outcomes and potentially alter the natural history for these children.


Assuntos
Aorta Torácica/anormalidades , Ecocardiografia/métodos , Artéria Pulmonar/anormalidades , Artéria Subclávia/anormalidades , Ultrassonografia Pré-Natal/métodos , Anel Vascular/diagnóstico , Aorta Torácica/diagnóstico por imagem , Broncoscopia , Pré-Escolar , Feminino , Humanos , Lactente , Masculino , Gravidez , Período Pré-Operatório , Artéria Pulmonar/diagnóstico por imagem , Estudos Retrospectivos , Artéria Subclávia/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Anel Vascular/cirurgia , Procedimentos Cirúrgicos Vasculares/métodos
17.
ASAIO J ; 67(12): 1329-1334, 2021 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-34860187

RESUMO

There are little data on postheart transplant (HT) outcomes for pediatric patients that were supported to HT with biventricular assist device (BiVAD). The United Network for Organ Sharing database was queried for patients <18 years old at time of HT between January 2005 and March 2018, excluding patients bridged with total artificial hearts and right ventricular assist device (VAD). Of 4,904 pediatric HT recipients, patients were grouped by no VAD support (3,934; 80.2%), left ventricular assist device only (736; 15%), and BiVAD (234; 4.8%). Overall graft survival analysis indicates crossing hazard rates between groups over time with the BiVAD group having a significantly lower graft survival at 1 year post-HT. A Cox model adjusted for age, era, diagnosis, and time by group interaction demonstrated increased 1 year hazard ratio (HR) of 8.5 (95% confidence intervals [CI]: 6.15-11.79) comparing BiVAD to no VAD. Comparable hazard between BiVAD and no VAD groups were found at 5 years (HR 1.01; 95% CI: 0.67-1.51), while lower hazard for the BiVAD group was found at 10 years post-HT (HR 0.07; 95% CI: 0.03-0.18). Although pre-HT BiVAD support leads to worse graft survival 1 year post-HT, long-term survival is acceptable.


Assuntos
Insuficiência Cardíaca , Transplante de Coração , Coração Auxiliar , Adolescente , Criança , Sobrevivência de Enxerto , Insuficiência Cardíaca/cirurgia , Transplante de Coração/efeitos adversos , Coração Auxiliar/efeitos adversos , Humanos , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
18.
World J Pediatr Congenit Heart Surg ; 12(5): 628-634, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34597206

RESUMO

BACKGROUND: Although valve-sparing repair remains ideal for patients with tetralogy of Fallot, the durability of valve-sparing repair and which patients may have been better served with a transannular patch remain unclear. METHODS: Retrospective review was performed of tetralogy of Fallot operations at our institution from January 2008 to December 2018. Standard demographic data were collected, including echocardiographic parameters, operative details, and clinical outcomes. Statistical analysis was performed comparing the transannular patch and valve-sparing repair groups. RESULTS: Sixty-seven patients underwent tetralogy of Fallot repair with a median age of 4.5 (3.2-6.0) months and weight of 5.8 (5.2, 6.7) kg. Seventeen (25%) patients underwent transannular patch repair and 50 (75%) patients underwent valve-sparing repair. There was no difference in age or weight between patients who underwent a transannular patch repair and those who underwent a valve-sparing repair. At last follow-up (median 42 months), there was a trend of a higher peak pulmonary valve/right ventricular outflow tract gradient (P = .06) in the valve-sparing group, but no difference in the pulmonary valve annulus z-scores. Additionally, the pulmonary valve z-scores in the valve-sparing group decreased from -2.3 ± 1.0 on predischarge echocardiogram of to -1.2 ± 1.6 on last follow-up, with the peak gradient on predischarge 23 (0-37) mm Hg remaining stable on last follow-up at 18 (0-29) mm Hg. There was one reoperation: pulmonary valve replacement six years after a transannular patch. CONCLUSIONS: Obtaining a postrepair pulmonary valve z-score of -2 yields satisfactory, stable valve-sparing repair with pulmonary valve growth, acceptable gradients, minimal regurgitation, and high freedom from reintervention during follow-up.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Insuficiência da Valva Pulmonar , Estenose da Valva Pulmonar , Valva Pulmonar , Tetralogia de Fallot , Humanos , Lactente , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/cirurgia , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/etiologia , Insuficiência da Valva Pulmonar/cirurgia , Estudos Retrospectivos , Tetralogia de Fallot/diagnóstico por imagem , Tetralogia de Fallot/cirurgia , Resultado do Tratamento
19.
World J Pediatr Congenit Heart Surg ; 12(3): 331-336, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33942684

RESUMO

BACKGROUND: Postoperative infections can occur during surgical replacement of pulse generators for pacemakers and implantable cardioverter-defibrillators. The incidence of infection is poorly documented in children and patients with adult congenital heart disease. The utility of surveillance cultures obtained from device pocket swabs is unknown in this group. METHODS: We reviewed surgical replacements of cardiovascular implantable pulse generators from 2010 to 2017. Two cohorts were defined. In a surveillance cohort (123 patients), aerobic and anaerobic culture swabs of the device pocket were obtained at the time of generator change. In a nonsurveillance cohort (107 patients), generator change occurred without obtaining cultures. RESULTS: During 230 generator changes (mean patient age 19 years; 77% with structural congenital heart disease), two clinical infections occurred at the surgical site (0.9% incidence). Neither infection occurred in the surveillance cohort. Cultures were positive in 12 (9.8%) of 123 patients in the surveillance cohort, but 11 of 12 were likely contaminants and none were subsequently associated with clinical disease. There was no association between clinical infection or positive surveillance cultures and the location of pulse generator, the presence of other concurrent surgeries, or a history of prior pocket infection. CONCLUSIONS: Clinical infection was rare after pulse generator change in children and young adults. No cases required reintervention on the pocket. Surveillance cultures did not improve clinical care. These data extend current recommendations that surveillance cultures are not required during generator change to the pediatric and young adult population.


Assuntos
Desfibriladores Implantáveis , Cardiopatias Congênitas , Marca-Passo Artificial , Adulto , Criança , Desfibriladores Implantáveis/efeitos adversos , Cardiopatias Congênitas/cirurgia , Humanos , Incidência , Marca-Passo Artificial/efeitos adversos , Complicações Pós-Operatórias , Adulto Jovem
20.
J Heart Lung Transplant ; 40(4): 251-259, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33579597

RESUMO

BACKGROUND: The Berlin Heart EXCOR Pediatric (EXCOR) ventricular assist device (VAD) was introduced in North America nearly 2 decades ago. The EXCOR was approved under Humanitarian Device Exemption status in 2011 and received post-market approval (PMA) in 2017 from Food and Drug Administration. Since the initial approval, the field of pediatric mechanical circulatory support has changed, specifically with regard to available devices, anticoagulation strategies, and the types of patients supported. This report summarizes the outcomes of patients supported with EXCOR from the Advanced Cardiac Therapies Improving Outcomes Network (ACTION) registry. These data were part of the PMA surveillance study (PSS) required by the Food and Drug Administration. METHODS: ACTION is a learning collaborative of over 40 pediatric heart failure programs worldwide, which collects data for all VAD implantations as one of its initiatives. All patients in North America with EXCOR implants reported to ACTION from 2018 to 2020 (n = 72) who had met an outcome were included in the EXCOR PSS group. This was compared with a historical, previously reported Berlin Heart EXCOR study group (Berlin Heart study [BHS] group, n = 320, 2007‒2014). RESULTS: Patients in the PSS group were younger, were smaller in weight/body surface area, were more likely to have congenital heart disease, and were less likely to receive a bi-VAD than those in the BHS group. Patients in the PSS group were less likely to be in Interagency Registry for Mechanically Assisted Circulatory Support Profile 1 and were supported for a longer duration. The primary anticoagulation therapy for 92% of patients in the PSS group was bivalirudin. Success, defined as being transplanted, being weaned for recovery, or being alive on a device at 180 days after implantation, was 86% in the PSS group compared with 76% in the BHS group. Incidence of stroke was reduced by 44% and the frequency of pump exchange by 40% in the PSS group compared with those in the BHS group. Similarly, all other adverse events, including major bleeding, were reduced in the PSS group. CONCLUSIONS: The PSS data, collected through ACTION, highlight the improvement in outcomes for patients supported with EXCOR compared with the outcomes in a historical cohort. These findings may be the result of changes in patient care practices over time and collaborative learning.


Assuntos
Aprovação de Equipamentos , Cardiopatias Congênitas/cirurgia , Insuficiência Cardíaca/terapia , Coração Auxiliar/normas , Avaliação de Resultados em Cuidados de Saúde , Vigilância da População/métodos , Sistema de Registros , Pré-Escolar , Feminino , Cardiopatias Congênitas/complicações , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/etiologia , Transplante de Coração , Humanos , Incidência , Lactente , Masculino , América do Norte/epidemiologia , Estudos Retrospectivos , Taxa de Sobrevida/tendências
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA